Overview
Everything that would normally be built into a substation building — transformer, switchgear, protection, auxiliary supply, lighting, ventilation and cable management — is installed and tested inside a container at the factory.
Capacity 500 kVA – 63 MVA. The unit ships as standard freight, arrives ready to connect, and can be relocated later if the site plan changes.
Key Features
- Capacity 500 kVA – 63 MVA
- Complete electrical room built and tested inside a shipping container
- Ships as standard freight, arrives ready to connect
- Relocatable — suits phased developments and temporary supply
- Ventilation, lighting, fire detection and auxiliary supply integrated
- Suitable for remote sites and fast-track project schedules
Typical Applications
Mining and remote industrial sites, solar and wind farms, temporary and phased power supply, and fast-track infrastructure projects.
Project configuration
| Assembly configuration | Containerised electrical room with a transformer, switchgear, protection and auxiliaries |
|---|---|
| Electrical ratings to confirm | Transformer-unit rating, complete assembly scope, voltage ratio and frequency |
| Auxiliary systems to confirm | Ventilation, fire detection, lighting and auxiliary supply |
| Logistics details to confirm | Outline, overall mass, lifting points and transport clearances |
The existing catalogue table lists ratings for a transformer compartment. Confirm the selected transformer rating and complete containerised assembly specification on the project schedule.
Technical Specifications
Technical Specifications
| No. | Item | Unit | High Voltage Unit | Transformer Unit | Low Voltage Unit |
|---|---|---|---|---|---|
| 1 | Rated Voltage | kV | 6, 10, 35 | 6, 10, 35 | 0.22, 0.38, 0.66 |
| 2 | Max. Operating Voltage | kV | 7.2, 12, 40.5 | – | – |
| 3 | Rated Frequency | Hz | 50 | ||
| 4 | Rated Capacity | kVA | – | 30~2000 | – |
| 5 | Rated Current | A | 400, 630, 1250 | – | 50~4000 |
| 6 | 1 min Power Frequency Withstand Voltage | kV | 42 (Phase-to-ground and phase-to-phase), 48 (Isolation gap) | – | 2.5 |
| 7 | (10kV) Lightning Impulse Withstand Voltage | kV | 75 (Phase-to-ground and phase-to-phase), 85 (Isolation gap) | – | – |
| 8 | (10kV) Rated Short-circuit Breaking Current | kA | 31.5 | – | – |
| 9 | Tapping Range | % | – | ±2×2.5%, ±5% | – |
| 10 | Vector Group | – | – | Yyn0, Dyn11 | – |
| 11 | Impedance Voltage | % | – | 4, 4.5, 6, 8 | – |
| 12 | Protection Grade (Standard Product) | – | IP33 | IP23 | IP33 |
| 13 | Sound Power Level | dB(A) | – | ≤ 50 | – |