Pre-Fabricated Containerised Substations

Containerised substations from 500 kVA to 63 MVA. The complete electrical room is built and commissioned inside a shipping container, then delivered as one unit — the fastest route to energising a remote or fast-track site.

Request a quote

Overview

Everything that would normally be built into a substation building — transformer, switchgear, protection, auxiliary supply, lighting, ventilation and cable management — is installed and tested inside a container at the factory.

Capacity 500 kVA – 63 MVA. The unit ships as standard freight, arrives ready to connect, and can be relocated later if the site plan changes.

Key Features

  • Capacity 500 kVA – 63 MVA
  • Complete electrical room built and tested inside a shipping container
  • Ships as standard freight, arrives ready to connect
  • Relocatable — suits phased developments and temporary supply
  • Ventilation, lighting, fire detection and auxiliary supply integrated
  • Suitable for remote sites and fast-track project schedules

Typical Applications

Mining and remote industrial sites, solar and wind farms, temporary and phased power supply, and fast-track infrastructure projects.

Project configuration

Assembly configuration Containerised electrical room with a transformer, switchgear, protection and auxiliaries
Electrical ratings to confirm Transformer-unit rating, complete assembly scope, voltage ratio and frequency
Auxiliary systems to confirm Ventilation, fire detection, lighting and auxiliary supply
Logistics details to confirm Outline, overall mass, lifting points and transport clearances

The existing catalogue table lists ratings for a transformer compartment. Confirm the selected transformer rating and complete containerised assembly specification on the project schedule.

Technical Specifications

Technical Specifications

No. Item Unit High Voltage Unit Transformer Unit Low Voltage Unit
1 Rated Voltage kV 6, 10, 35 6, 10, 35 0.22, 0.38, 0.66
2 Max. Operating Voltage kV 7.2, 12, 40.5 – –
3 Rated Frequency Hz 50
4 Rated Capacity kVA – 30~2000 –
5 Rated Current A 400, 630, 1250 – 50~4000
6 1 min Power Frequency Withstand Voltage kV 42 (Phase-to-ground and phase-to-phase), 48 (Isolation gap) – 2.5
7 (10kV) Lightning Impulse Withstand Voltage kV 75 (Phase-to-ground and phase-to-phase), 85 (Isolation gap) – –
8 (10kV) Rated Short-circuit Breaking Current kA 31.5 – –
9 Tapping Range % – ±2×2.5%, ±5% –
10 Vector Group – – Yyn0, Dyn11 –
11 Impedance Voltage % – 4, 4.5, 6, 8 –
12 Protection Grade (Standard Product) – IP33 IP23 IP33
13 Sound Power Level dB(A) – ≤ 50 –